Perbandingan Isolasi DNA Bakteri Escherichia coli dengan Metode Heat Treatment dan Filter Based Kit berdasarkan Nilai Limit of Detection dan Limit of Quantification

Show simple item record

dc.contributor.author Muhammad, Brillian Nur
dc.date.accessioned 2020-11-17T02:45:33Z
dc.date.available 2020-11-17T02:45:33Z
dc.date.issued 2020-07-21
dc.identifier.uri http://repository.unisma.ac.id/handle/123456789/338
dc.description.abstract Introduction: One simple and rapid DNA isolation method is by heat treatment. However, it unknown whether the result of this method has the same quality compared to the more commonly used filter based kit. This research aims compare heat treatment and filter based kit DNA isolation methods based on its limit of detection (LOD) and limit of quantification (LOQ) from DNA isolation yield from E. coli. Method: This research is an in vitro laboratorium experimental research method. The E. coli concentration in this study is obtained through purposive samplingwith a concentration of 101 – 104 CFU/ml. Heat treatment and filter based kit method are DNA isolation methods used in this study. The data analysis uses ANOVA and Least Significant Diference (LSD) test. Result: Optimal yield of heat treatment method was found at a bacterial concentration of 10.000 CFU/ml (p=0.000) and 1000 CFU/ml (p=0.002). While the optimal yield of filter based kit was found at 10.000 CFU/ml (p=0.003), 1000 CFU/ml (p=0.009) and 100 CFU/ml (p=0.033). The purity value of both heat treatment and filter based kit method did not reach 1,7-2,0. The heat treatment's LOD was 2,39 ng/µl, while the filter based kit's LOD was 4,06 ng/µl. The heat treatment's LOQ was 6, 43 ng/µl, while the filter based kit's LOQ was 8, 10 ng/µl. Conclusion: According to limit of detection, the heat treatment method has the minimum bacterial concentration of 1000 CFU/ml. Whereas, the filter based kit method has the minimum bacterial concentration of 10 CFU/ml. Based on the method comparison, filter based kit method has higher yield than heat treatment method. Keyword: DNA isolation, heat treatment, filter based kit, Escherichia coli en_US
dc.language.iso other en_US
dc.publisher Universitas Islam Malang en_US
dc.subject Isolasi DNA en_US
dc.subject Heat Treatment en_US
dc.subject Filter Based Kit en_US
dc.subject Escherichia coli en_US
dc.title Perbandingan Isolasi DNA Bakteri Escherichia coli dengan Metode Heat Treatment dan Filter Based Kit berdasarkan Nilai Limit of Detection dan Limit of Quantification en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Kolom Pencarian


Browse

My Account